Quickguide_digital_Sliding doors

An installation manual in your pocket Always up-to-date and always within reach, download the app today! SLIDING DOOR You can always access the installation manuals from your PC at: install.idealcombi.com When you have downloaded the app and selected language, select the product series and opening type you are installing. You will then see a list of content, simply tap the section from which you need information. In the app you will find a mix of text, drawings and videos. These will explain the different aspects of the installation and ensure you install the windows and doors correctly.

Receipt and storage According to the DVV installation requirements it is the contractor installing the windows and doors that is responsible for complying with the installation guidelines set out by both DVV and Idealcombi. Claims or service requests that is caused by faulty installation or maintenance are not covered by guarantee.. When unloading and handling the elements, use tools and methods which do not damage the elements or endanger anyone working on-site. Upon receipt, the buyer must check that the consignment complies with the agreement and that the units are free from apparent defects, faults or transportation damage. If any issues are discovered upon delivery it must be written in the delivery note, please contact Idealcombi’s Service Department on tel. 01582 860 940 before installing the units. A fitted unit is considered an accepted unit unless otherwise agreed in writing with Idealcombi’s service department. Stickers and cork chips on window glass and other protective packaging must only be removed just before installing the units. Note: Failing to remove these can result in damages to the glass over long period. If stored outdoors, the units must be placed on battens or pallets to keep them clear of the ground. The units must be covered with a suitable and secure material to protect them from precipitation and dirt. Allow for sufficient ventilation around the units in order to reduce the risk of condensation forming underneath the covering and excessive heat building up due to direct sunlight. Individual window units should be stored under a roof structure, in a container or preferably inside. Our doors and windows are supplied with a small tin of paint in the colour of the internal finish. This paint is for the fitter in case of minor damage during installation. Idealcombi’s Service Department is always willing to offer help and advice on surface treatment maintenance and on where to buy additional paint in a particular colour. To ensure optimal function and operation, windows and doors must be installed correctly. Incorrect installation can result in faulty windows and doors. Damage to products installed incorrectly will not be covered by the warranty. You are always welcome to contact our service team if you have any concerns regarding installation. You can reach the service team on tel: 01582 860 940. General user manual Find more details in the installation app or at install.idealcombi.com Sliding doors supplied with an espagnolette are operated with a single handle placed on the sash. (Futura+ sliding door with 70 mm threshold has a handle each side of the sash). The espag has adjustable mushroom bolts that lock into the keeps securing the sliding door in a closed position. This helps to prevent forced entry. The mushroom bolt can be adjusted as needed to ensure the sash has a tight seal against the frame. IC Sliding door Turn the handle 180° to a vertical position and the door will move out 8mm from the frame. The door can then slide past the fixed light, on the outside. It is not possible to fix the door in an opened position. If the handle is turned to the closed position while the door is open you risk damaging the frame. On the top track there is an stop block, making sure the door will not open too far. Futura+ Slidling door with low threshold To open the door turn the mullion lock to a horisontal position before the handle on the door is turned to a horisontal position, allowing the door to slide along the outside of the fixed light. On the top track there is an stop block, making sure the door will not open too far. On the jamb there is a stop, ensuring the door does not hit the keeps while closing. Futura+ Sliding door with 70 mm threshold. To protect the TurnPlus ventilation function from damage during construction, a red plastic blocker has been fitted. Remove the red plastic blockers when you start using the door. The door is opened by turning the two handles on the main slider to a horizontal position, then push out an slide the door to the side. The door can be height adjusted for smooth operation. Open doors and loosen the loocking screw on the bottom slider. Video: bit.ly/HeightAdjust With a round ø4 mm metal tool, the bushing can be turned to adjust the door up and down. It can be necessary to unload the slider from the weight of the door while adjusting. Tighten the locking screw again after adjustment is complete. The two stops on the bottom rail ensures the doors do not open too much, and that the door leaf is positioned correct in the frame. The stop on the closing side can be adjusted for a perfect fit. Maintenance - Lubricate all moving parts and locks as needed, and at least once a year. Handle positions TurnPlus Ventilation Open Closed Closed Vent pos. 2 Vent pos. 3 Vent pos. 1 3 2 1 1 2 “click” “click” 3 Handle positions TurnPlus Ventilation Open Closed Closed Vent pos. 2 Vent pos. 3 Vent pos. 1 3 2 1 1 2 “click” “click” 3 Locking screw Pinch hazard! Pinch hazard! 2. Locking screws Not visible from this angle 1. Vertical adjustment Detailed user manual can be found on idealcombi.com/brochures

Installation in general A window is never better than its installation… We know, that you already know how to fit windows perfectly. But here is a friendly reminder of how you can ensure a top professional job when installing Idealcombi windows and doors. 10 top tips before you get started: • Read the installation manual. • Use packers correctly. • Always place the fixings correctly. • Make sure everything is plumb and level. • Keep heads, jambs, and sills/threshold straight. • Check the diagonal measures. • Clean rebate and ironmongery from building dust. • Function test and adjustment of ironmongery and locking points. • Lubricate ironmongery and moving parts. (BUT NOT FRICTION STAYS) • Treat rubber seals with silicone. Be proud of a job well done – It is the installer that makes the last and crucial difference for the customer! Packers Units are placed in the aperture and packed up with wedges under the jambs and mullions. For other permanent wedging see the respective opening types on the following pages. Packers and wedges must always support both timber and idealcore, be moisture resistant and have a width of min. 40 mm. Full depth packers must be used on doors with fibre threshold with a distance of max. 300 mm. Sliding door with low threshold continous packing. Fully supportive packer must be used on units with fibre threshold. Improved strength Packers can be placed by all closing/locking points to increase strength in case of break-ins. Be careful! No packers are allowed at the head if there is a risk of load transferred from the construction above. Tolerances The frame is placed in the aperture and there must be uniform sealing space by the jambs and the head. Consider the use of sills and/or finished floor levels. Tolerance around the window/door should be around 12 mm. Diagonal measures The frame must be plumb and square. The frame must be secured to ensure a tight seal when the sash is closed - with a uniform gap between sash and frame. The tolerance on diagonal measures is max. ±2 mm. Installing specific element types On the following pages you will get a quick overview of installing the different element types. In idealcombi’s installation app or at install.idealcombi.com you will find more detailed installation information in words, pictures and videos. Find more details in the installation app or on install.idealcombi.com Installation - a quick overview Packers Packer width min. 40 mm. Packing type 1: Mandatory permanent packers. Packing type 2: Depending on the fixing screw used, the responsible installer must consider the need for packing type 2. In these considerations, make sure that forces illustrated by ,must be absorbed by the surrounding construction. IdealcoreTM Wedges are placed at the corners. Never hit the frame directly, always use a pad, pre-drilling through IdealcoreTM must never be done with a hammer drill. This will lead to rejection of material on the back, and thus greatly weaken the frame fixings. When installing the unit, distance must be controlled with a wedge or permanent packer Fixing Windows and external doors must always be secured to the surrounding building with suitable screws or brackets, Fixing locations are industry standard: 150mm from each end or mullion, then at 450 - 600mm centres. Find more details in the installation app or on install.idealcombi.com

Find more details in the installation app or on install.idealcombi.com Installation - a quick overview Installation - a quick overview Find more details in the installation app or on install.idealcombi.com

AFTER SALES & SERVICE After Sales If you want to purchase accessories for your windows or replacement parts, you can do this through our After Sales department. We will require specific order details to purchase accessories or extras. You can find these specifications on the spacer bar between the glass or on your order confirmation. See below for contact information. Report a product issue We do our best to deliver high-quality windows and doors without defects. But there can be no rules without exceptions! If, against expectations, defects occur during production, transport or delivery, you must report any issues as soon as it is discovered. In case of delivery damage, this must be noted on the DSV delivery note when the goods are delivered. Failure to note any issues will not be covered by the warranty. You must not install the elements before you have the approval of our Service Department. We strive to process reports of issues quickly and professionally, and we take any contact regarding defects on our products very seriously. Remember not to fit damaged or faulty units without first consulting with Idealcombi’s Service Department. Tel.: +44 (0)1582 860 940 Mail: service@idealcombi.com © Idealcombi A/S 12.2021 - No5 Idealcombi UK Ltd. • Milton Keynes • MK6 2TA • Tel: 01582 860 940 • service@idealcombi.com

RkJQdWJsaXNoZXIy MjgyMTg=